- Consumer grade. This type of air compressors are designed for applications that require small amount of air and are suitable to be used inside the house. Applications include inflating tires, sporting materials and toys. If you need the compressor for the following task then this grade of equipment is suitable. Aside from inflating various things inside the house, consumer grade can also operate air tools that need a small amount of air such as staplers and brad guns. Quincy air compressor is available in consumer grade. If you need the air compressor for heavy duty applications or require it to be used in various tools all at once then it is best to purchase a powerful compressor.
- Contractor grade. This type of air compressor is designed to be used in job sites. This is recommended for use of building contractors because it is very portable and can be moved using wheeled cart, attachment to a vehicle and some can be even hand carried. This type of air compressor can be used in various applications but its primary purpose is to operate repair tools on roadside jobs and nail guns.
- Commercial grade. If you want an air compressor that can operate multiple air tools and have higher capacity, commercial grade air compressors is recommended for you. The compressed air provided by these types comes in steady supply and can operate for 24 hours without stopping. These compressors are designed for heavy duty operations and use the latest technology while giving superior performance. This is more expensive compared to other grades.
- The level of the fluid and oil of the machine should be checked daily.
- For small machines, oil should be changed once every 500 hours of operation while for larger machines it should be changed once every 1,000 hours of operation.
- The air filters of the air compressor should also be changed once every 500 hours of operation.
- In the case of the separator element, it should be changed once every 1,000 hours for small machines and 2,000 hours for larger machines. This is an important part of the compressor because it makes sure that oil is not used excessively.
- Hoses used by the air compressor should be checked in a regular basis. Any sign of damage or wear and tear indicates that it should be changed.
- The airend should undergo an overhaul once the machine has reached 8,000 to 10,000 hours of operation.
- The fuel tank must be cleaned every year.
- The operating temperature of the machine can be controlled by keeping the heat exchangers clean.